{"id":6421,"date":"2026-11-19T14:41:22","date_gmt":"2026-11-19T11:41:22","guid":{"rendered":"https:\/\/www.clinipower.fi\/?p=6421"},"modified":"2026-11-19T14:41:22","modified_gmt":"2026-11-19T11:41:22","slug":"post-market-surveillance-under-the-mdr-what-must-the-manufacturer-monitor-after-placing-a-device-on-the-market","status":"publish","type":"post","link":"https:\/\/www.clinipower.fi\/en\/post-market-surveillance-under-the-mdr-what-must-the-manufacturer-monitor-after-placing-a-device-on-the-market\/","title":{"rendered":"Post-market surveillance under the MDR: what must the manufacturer monitor after placing a device on the market?"},"content":{"rendered":"<p dir=\"ltr\">A manufacturer\u2019s responsibility for the safety of a medical device does not end with CE marking. The MDR requires manufacturers to monitor their device throughout its lifecycle, collect information on its performance and respond to findings. Post-market surveillance is part of the quality management system and applies to all medical devices regardless of risk class or device type. For IVD devices, corresponding requirements are set out in the IVDR.<\/p>\n<h3 dir=\"ltr\" aria-level=\"5\">What does post-market surveillance mean under the MDR?<\/h3>\n<p dir=\"ltr\">Post-market surveillance is a systematic activity in which the manufacturer collects and analyses data on the safety and performance of a device on the market. The aim is to identify new risks, ensure the benefit-risk ratio remains acceptable and update the device documentation when necessary. The MDR requires the system to be proportionate to the device\u2019s risk class and appropriate for the type of device.<\/p>\n<h3 dir=\"ltr\" aria-level=\"5\">What data must the manufacturer collect?<\/h3>\n<p dir=\"ltr\">Data is collected actively from various sources and processed systematically. Typical sources include:<\/p>\n<ul dir=\"ltr\">\n<li>feedback and complaints from users, distributors and importers<\/li>\n<li>serious and non-serious incidents and adverse effects<\/li>\n<li>scientific and technical literature<\/li>\n<li>registries and databases<\/li>\n<li>publicly available information on similar devices<\/li>\n<li>service and repair records<\/li>\n<\/ul>\n<p dir=\"ltr\">Procedures for collecting and evaluating data are part of the quality management system.<\/p>\n<h3 dir=\"ltr\" aria-level=\"5\">What documents must the manufacturer prepare?<\/h3>\n<p dir=\"ltr\">The foundation of post-market surveillance is the PMS plan, which forms part of the technical documentation. It describes what data is collected, how it is evaluated and how the results are used. More on the content of the documentation can be found in the article <em>MDR technical documentation<\/em>.<\/p>\n<p dir=\"ltr\">A summary of the collected data is reported according to risk class:<\/p>\n<ul dir=\"ltr\">\n<li>Class I: PMS report, updated when necessary<\/li>\n<li>Class IIa: Periodic Safety Update Report (PSUR), updated when necessary and at least every two years<\/li>\n<li>Classes IIb and III: PSUR, updated at least annually<\/li>\n<\/ul>\n<p dir=\"ltr\">For Class III and implantable devices, the PSUR is submitted to the notified body for evaluation. For other classes, reports must be made available to the notified body and authorities upon request.<\/p>\n<h3 dir=\"ltr\" aria-level=\"5\">When must an incident be reported to the authorities?<\/h3>\n<p dir=\"ltr\">The manufacturer must report serious incidents to the competent authority, which in Finland is Fimea. Reporting deadlines depend on the severity of the situation:<\/p>\n<ul dir=\"ltr\">\n<li>serious incident: immediately and no later than 15 days after becoming aware of it<\/li>\n<li>serious public health threat: immediately and no later than 2 days after becoming aware of it<\/li>\n<li>death or unanticipated serious deterioration in a person\u2019s state of health: immediately and no later than 10 days after becoming aware of it<\/li>\n<\/ul>\n<p dir=\"ltr\">In addition, the manufacturer must report any statistically significant increase in the frequency or severity of non-serious incidents or expected undesirable side effects (trend reporting). If the situation requires action concerning devices already in use, a field safety corrective action is carried out and users are informed.<\/p>\n<h3 dir=\"ltr\" aria-level=\"5\">What is PMCF and how does it relate to clinical evaluation?<\/h3>\n<p dir=\"ltr\">Post-market clinical follow-up (PMCF) is an ongoing process in which clinical data is collected on the use of a CE-marked device. The data gathered through PMCF updates the clinical evaluation and supports the assessment of the device\u2019s benefit-risk ratio. The PMCF plan and report are an important part of the documentation, and deficiencies in them are a common audit finding.<\/p>\n<h3 dir=\"ltr\" aria-level=\"5\">What are the key takeaways?<\/h3>\n<p dir=\"ltr\">Post-market surveillance works best when it is planned already during product development and integrated into risk management, clinical evaluation and quality management system procedures. The collected data must be used systematically: findings are used to update the risk analysis and documentation and, when necessary, to make changes to the product itself. It is wise to define responsibilities, data sources and reporting processes clearly before the first complaint arrives.<\/p>\n<p dir=\"ltr\">Clinipower supports manufacturers in planning post-market surveillance, preparing PMS and PMCF documentation and developing quality management systems. Tell us about your situation and we will assess together what kind of support would serve you best.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>A manufacturer\u2019s responsibility for the safety of a medical device does not end with CE marking. The MDR requires manufacturers to monitor their device throughout its lifecycle, collect information on its performance and respond to findings. Post-market surveillance is part of the quality management system and applies to all medical devices regardless of risk class [&#8230;]<\/p>\n<p><a class=\"btn btn-secondary understrap-read-more-link\" href=\"https:\/\/www.clinipower.fi\/en\/post-market-surveillance-under-the-mdr-what-must-the-manufacturer-monitor-after-placing-a-device-on-the-market\/\">Read More&#8230;<span class=\"screen-reader-text\"> from Post-market surveillance under the MDR: what must the manufacturer monitor after placing a device on the market?<\/span><\/a><\/p>\n","protected":false},"author":16,"featured_media":2150,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[37,36],"tags":[],"class_list":["post-6421","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-product-development-and-processes","category-quality-and-regulation"],"acf":[],"gutentor_comment":0,"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Post-market surveillance under the MDR: what must the manufacturer monitor after placing a device on the market? - Clinipower Finland Oy<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.clinipower.fi\/en\/post-market-surveillance-under-the-mdr-what-must-the-manufacturer-monitor-after-placing-a-device-on-the-market\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Post-market surveillance under the MDR: what must the manufacturer monitor after placing a device on the market? - Clinipower Finland Oy\" \/>\n<meta property=\"og:description\" content=\"A manufacturer\u2019s responsibility for the safety of a medical device does not end with CE marking. The MDR requires manufacturers to monitor their device throughout its lifecycle, collect information on its performance and respond to findings. Post-market surveillance is part of the quality management system and applies to all medical devices regardless of risk class [...]Read More... from Post-market surveillance under the MDR: what must the manufacturer monitor after placing a device on the market?\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.clinipower.fi\/en\/post-market-surveillance-under-the-mdr-what-must-the-manufacturer-monitor-after-placing-a-device-on-the-market\/\" \/>\n<meta property=\"og:site_name\" content=\"Clinipower Finland Oy\" \/>\n<meta property=\"article:published_time\" content=\"2026-11-19T11:41:22+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.clinipower.fi\/wp-content\/uploads\/2021\/09\/Mielipiteet-banner.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1920\" \/>\n\t<meta property=\"og:image:height\" content=\"795\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Sylvia Syv\u00e4nen\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Sylvia Syv\u00e4nen\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.clinipower.fi\\\/en\\\/post-market-surveillance-under-the-mdr-what-must-the-manufacturer-monitor-after-placing-a-device-on-the-market\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.clinipower.fi\\\/en\\\/post-market-surveillance-under-the-mdr-what-must-the-manufacturer-monitor-after-placing-a-device-on-the-market\\\/\"},\"author\":{\"name\":\"Sylvia Syv\u00e4nen\",\"@id\":\"https:\\\/\\\/www.clinipower.fi\\\/en\\\/#\\\/schema\\\/person\\\/82701851d0878467369e02283af1af59\"},\"headline\":\"Post-market surveillance under the MDR: what must the manufacturer monitor after placing a device on the market?\",\"datePublished\":\"2026-11-19T11:41:22+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.clinipower.fi\\\/en\\\/post-market-surveillance-under-the-mdr-what-must-the-manufacturer-monitor-after-placing-a-device-on-the-market\\\/\"},\"wordCount\":666,\"publisher\":{\"@id\":\"https:\\\/\\\/www.clinipower.fi\\\/en\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.clinipower.fi\\\/en\\\/post-market-surveillance-under-the-mdr-what-must-the-manufacturer-monitor-after-placing-a-device-on-the-market\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.clinipower.fi\\\/wp-content\\\/uploads\\\/2021\\\/09\\\/Mielipiteet-banner.jpg\",\"articleSection\":[\"Product development and processes\",\"Quality and regulation\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.clinipower.fi\\\/en\\\/post-market-surveillance-under-the-mdr-what-must-the-manufacturer-monitor-after-placing-a-device-on-the-market\\\/\",\"url\":\"https:\\\/\\\/www.clinipower.fi\\\/en\\\/post-market-surveillance-under-the-mdr-what-must-the-manufacturer-monitor-after-placing-a-device-on-the-market\\\/\",\"name\":\"Post-market surveillance under the MDR: what must the manufacturer monitor after placing a device on the market? - Clinipower Finland Oy\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.clinipower.fi\\\/en\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.clinipower.fi\\\/en\\\/post-market-surveillance-under-the-mdr-what-must-the-manufacturer-monitor-after-placing-a-device-on-the-market\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.clinipower.fi\\\/en\\\/post-market-surveillance-under-the-mdr-what-must-the-manufacturer-monitor-after-placing-a-device-on-the-market\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.clinipower.fi\\\/wp-content\\\/uploads\\\/2021\\\/09\\\/Mielipiteet-banner.jpg\",\"datePublished\":\"2026-11-19T11:41:22+00:00\",\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.clinipower.fi\\\/en\\\/post-market-surveillance-under-the-mdr-what-must-the-manufacturer-monitor-after-placing-a-device-on-the-market\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.clinipower.fi\\\/en\\\/post-market-surveillance-under-the-mdr-what-must-the-manufacturer-monitor-after-placing-a-device-on-the-market\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.clinipower.fi\\\/wp-content\\\/uploads\\\/2021\\\/09\\\/Mielipiteet-banner.jpg\",\"contentUrl\":\"https:\\\/\\\/www.clinipower.fi\\\/wp-content\\\/uploads\\\/2021\\\/09\\\/Mielipiteet-banner.jpg\",\"width\":1920,\"height\":795},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.clinipower.fi\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/www.clinipower.fi\\\/en\\\/\",\"name\":\"Clinipower Finland Oy\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.clinipower.fi\\\/en\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.clinipower.fi\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.clinipower.fi\\\/en\\\/#organization\",\"name\":\"Clinipower Oy\",\"url\":\"https:\\\/\\\/www.clinipower.fi\\\/en\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.clinipower.fi\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"\",\"contentUrl\":\"\",\"caption\":\"Clinipower Oy\"},\"image\":{\"@id\":\"https:\\\/\\\/www.clinipower.fi\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.clinipower.fi\\\/en\\\/#\\\/schema\\\/person\\\/82701851d0878467369e02283af1af59\",\"name\":\"Sylvia Syv\u00e4nen\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/f08683e6f46efa3950a6721f89c14d82302c8228e0358ef04fd1767ac70dae6c?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/f08683e6f46efa3950a6721f89c14d82302c8228e0358ef04fd1767ac70dae6c?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/f08683e6f46efa3950a6721f89c14d82302c8228e0358ef04fd1767ac70dae6c?s=96&d=mm&r=g\",\"caption\":\"Sylvia Syv\u00e4nen\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Post-market surveillance under the MDR: what must the manufacturer monitor after placing a device on the market? - Clinipower Finland Oy","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.clinipower.fi\/en\/post-market-surveillance-under-the-mdr-what-must-the-manufacturer-monitor-after-placing-a-device-on-the-market\/","og_locale":"en_US","og_type":"article","og_title":"Post-market surveillance under the MDR: what must the manufacturer monitor after placing a device on the market? - Clinipower Finland Oy","og_description":"A manufacturer\u2019s responsibility for the safety of a medical device does not end with CE marking. The MDR requires manufacturers to monitor their device throughout its lifecycle, collect information on its performance and respond to findings. Post-market surveillance is part of the quality management system and applies to all medical devices regardless of risk class [...]Read More... from Post-market surveillance under the MDR: what must the manufacturer monitor after placing a device on the market?","og_url":"https:\/\/www.clinipower.fi\/en\/post-market-surveillance-under-the-mdr-what-must-the-manufacturer-monitor-after-placing-a-device-on-the-market\/","og_site_name":"Clinipower Finland Oy","article_published_time":"2026-11-19T11:41:22+00:00","og_image":[{"width":1920,"height":795,"url":"https:\/\/www.clinipower.fi\/wp-content\/uploads\/2021\/09\/Mielipiteet-banner.jpg","type":"image\/jpeg"}],"author":"Sylvia Syv\u00e4nen","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Sylvia Syv\u00e4nen","Est. reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.clinipower.fi\/en\/post-market-surveillance-under-the-mdr-what-must-the-manufacturer-monitor-after-placing-a-device-on-the-market\/#article","isPartOf":{"@id":"https:\/\/www.clinipower.fi\/en\/post-market-surveillance-under-the-mdr-what-must-the-manufacturer-monitor-after-placing-a-device-on-the-market\/"},"author":{"name":"Sylvia Syv\u00e4nen","@id":"https:\/\/www.clinipower.fi\/en\/#\/schema\/person\/82701851d0878467369e02283af1af59"},"headline":"Post-market surveillance under the MDR: what must the manufacturer monitor after placing a device on the market?","datePublished":"2026-11-19T11:41:22+00:00","mainEntityOfPage":{"@id":"https:\/\/www.clinipower.fi\/en\/post-market-surveillance-under-the-mdr-what-must-the-manufacturer-monitor-after-placing-a-device-on-the-market\/"},"wordCount":666,"publisher":{"@id":"https:\/\/www.clinipower.fi\/en\/#organization"},"image":{"@id":"https:\/\/www.clinipower.fi\/en\/post-market-surveillance-under-the-mdr-what-must-the-manufacturer-monitor-after-placing-a-device-on-the-market\/#primaryimage"},"thumbnailUrl":"https:\/\/www.clinipower.fi\/wp-content\/uploads\/2021\/09\/Mielipiteet-banner.jpg","articleSection":["Product development and processes","Quality and regulation"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/www.clinipower.fi\/en\/post-market-surveillance-under-the-mdr-what-must-the-manufacturer-monitor-after-placing-a-device-on-the-market\/","url":"https:\/\/www.clinipower.fi\/en\/post-market-surveillance-under-the-mdr-what-must-the-manufacturer-monitor-after-placing-a-device-on-the-market\/","name":"Post-market surveillance under the MDR: what must the manufacturer monitor after placing a device on the market? - Clinipower Finland Oy","isPartOf":{"@id":"https:\/\/www.clinipower.fi\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.clinipower.fi\/en\/post-market-surveillance-under-the-mdr-what-must-the-manufacturer-monitor-after-placing-a-device-on-the-market\/#primaryimage"},"image":{"@id":"https:\/\/www.clinipower.fi\/en\/post-market-surveillance-under-the-mdr-what-must-the-manufacturer-monitor-after-placing-a-device-on-the-market\/#primaryimage"},"thumbnailUrl":"https:\/\/www.clinipower.fi\/wp-content\/uploads\/2021\/09\/Mielipiteet-banner.jpg","datePublished":"2026-11-19T11:41:22+00:00","inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.clinipower.fi\/en\/post-market-surveillance-under-the-mdr-what-must-the-manufacturer-monitor-after-placing-a-device-on-the-market\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.clinipower.fi\/en\/post-market-surveillance-under-the-mdr-what-must-the-manufacturer-monitor-after-placing-a-device-on-the-market\/#primaryimage","url":"https:\/\/www.clinipower.fi\/wp-content\/uploads\/2021\/09\/Mielipiteet-banner.jpg","contentUrl":"https:\/\/www.clinipower.fi\/wp-content\/uploads\/2021\/09\/Mielipiteet-banner.jpg","width":1920,"height":795},{"@type":"WebSite","@id":"https:\/\/www.clinipower.fi\/en\/#website","url":"https:\/\/www.clinipower.fi\/en\/","name":"Clinipower Finland Oy","description":"","publisher":{"@id":"https:\/\/www.clinipower.fi\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.clinipower.fi\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.clinipower.fi\/en\/#organization","name":"Clinipower Oy","url":"https:\/\/www.clinipower.fi\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.clinipower.fi\/en\/#\/schema\/logo\/image\/","url":"","contentUrl":"","caption":"Clinipower Oy"},"image":{"@id":"https:\/\/www.clinipower.fi\/en\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.clinipower.fi\/en\/#\/schema\/person\/82701851d0878467369e02283af1af59","name":"Sylvia Syv\u00e4nen","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/f08683e6f46efa3950a6721f89c14d82302c8228e0358ef04fd1767ac70dae6c?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/f08683e6f46efa3950a6721f89c14d82302c8228e0358ef04fd1767ac70dae6c?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/f08683e6f46efa3950a6721f89c14d82302c8228e0358ef04fd1767ac70dae6c?s=96&d=mm&r=g","caption":"Sylvia Syv\u00e4nen"}}]}},"featured_image_src":"https:\/\/www.clinipower.fi\/wp-content\/uploads\/2021\/09\/Mielipiteet-banner-600x400.jpg","featured_image_src_square":"https:\/\/www.clinipower.fi\/wp-content\/uploads\/2021\/09\/Mielipiteet-banner-600x600.jpg","author_info":{"display_name":"Sylvia Syv\u00e4nen","author_link":"https:\/\/www.clinipower.fi\/en\/author\/sylvia\/"},"_links":{"self":[{"href":"https:\/\/www.clinipower.fi\/en\/wp-json\/wp\/v2\/posts\/6421","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.clinipower.fi\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.clinipower.fi\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.clinipower.fi\/en\/wp-json\/wp\/v2\/users\/16"}],"replies":[{"embeddable":true,"href":"https:\/\/www.clinipower.fi\/en\/wp-json\/wp\/v2\/comments?post=6421"}],"version-history":[{"count":1,"href":"https:\/\/www.clinipower.fi\/en\/wp-json\/wp\/v2\/posts\/6421\/revisions"}],"predecessor-version":[{"id":6422,"href":"https:\/\/www.clinipower.fi\/en\/wp-json\/wp\/v2\/posts\/6421\/revisions\/6422"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.clinipower.fi\/en\/wp-json\/wp\/v2\/media\/2150"}],"wp:attachment":[{"href":"https:\/\/www.clinipower.fi\/en\/wp-json\/wp\/v2\/media?parent=6421"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.clinipower.fi\/en\/wp-json\/wp\/v2\/categories?post=6421"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.clinipower.fi\/en\/wp-json\/wp\/v2\/tags?post=6421"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}